JAKSA Solenoid Valves

2/2 SOLENOID VALVES FOR VACUUM SERVICE

3/8" - 6/4"


JAKSA Solenoid Valves for Vacuum Service

TECHNICAL DATA:

  • Internal parts: stainless steel
  • Seals: NBR, FPM
  • Fluid temperature: -10°C to +90°C
  • Ambient temperature: max +60°C
  • Viscosity: max 21 mm2/s
  • Response time: 5 - 120 ms
  • Voltage: 230, 115, 48, 24 V AC / 24, 12 V DC
  • Duty cycle: continuous (ED100%)
  • Electrical protection: IP65 (with plug to ISO 4400)
    Long term use in humid environment requires the use of sealing sets.

2/2 Closed when de-energised (NC)

Ports Orifice size
[mm]
Kv
[l/min]
(water at 1 bar)
Minimum
ABSOLUTE
differential pressure
[mbar]
Body Seal Mass
[kg]
Coil type Model Order code
(click for details)
Fig.
G3/8 7 13 15 Brass NBR 0.52 TM35 D224 320717 1
G1/2 10 25 15 Brass NBR 0.57 TM35 D240 340481 2
G1/2 12 40 15 Brass NBR 0.43 TM30 M2451 301702 3
G3/4 18 65 15 Brass NBR 0.76 TM35 M2521 301701
G1 25 180 15 Brass NBR 1.2 TM35 M2621 301709
G6/4 40 330 15 Brass NBR 2.75 TM40 M275 370810
G3/4 18 70 15 Brass NBR 0.66 TM30 M250 350510 4
G1 25 180 15 Brass NBR 1.2 TM30 M260 360518
G6/4 40 330 15 Brass NBR 2.4 TM30 M270 370511
G2 50 630 15 Brass EPDM 4.5 TM35 M286 390544

2/2 Open when de-energised (NO)

Ports Orifice size
[mm]
Kv
[l/min]
(water at 1 bar)
Minimum
ABSOLUTE
differential pressure
[mbar]
Body Seal Mass
[kg]
Coil type Model Order code
(click for details)
Fig.
G3/4 18 70 15 Brass NBR 0.66 TM30 M250NO 359511 4
G1 25 180 15 Brass NBR 1.2 TM30 M260NO 369510
G6/4 40 330 15 Brass NBR 2.4 TM30 M270NO 379510

3/2 Closed when de-energised (NC)

Ports Orifice size
[mm]
Kv
[l/min]
(water at 1 bar)
Minimum
ABSOLUTE
differential pressure
[mbar]
Body Seal Mass
[kg]
Coil type Model Order code
(click for details)
Fig.
G1/4 4.5 7.5 15 Brass NBR 0.52 TM35 D32NO/NC 330742 5

OPTIONS:

top of page | download/print PDF version